(1) NEW 10 Ton Magnum Bench Model Gap Frame Hydraulic Press
Ton | 10 T | |
Bed L-R | 16.5 in | |
Bed F-B | 13 in | |
Stroke | 8 in | |
Daylight Opening | 16 in | |
Speed | 400 ipm | |
Dimensions | 32" lr x 43" fb x 49" high | 32" lr x 43" fb x 49" high |
Weight | 1,750# | 1,750# |
NOTE: 18 Months Parts Warranty
Capacity: 2.1 - 10.4 Ton
Stroke: 1" to 8"
Daylight: 16"
Shut Height: 8"
Throat: 8"
Bolster: 16.5" lr x 13" fb
Speeds:
Rapid: 400 ipm
Pressing: 150 ipm
Return: 240 ipm
Cycles per minute: 1" stroke: 78
Cycles per minute: 4" stroke: 31
Reservoir Capacity: 20 Gallons
Motor: 7.5HP TEFC
Voltage: 230/460 VAC / 3ph / 60Hz
OPTIPONS AVIALABLE:
Banner Zero Force Opto Touch Palm Buttons with Finger Guards
Single Stroke Automatic Circuit menu selection allows press to be cycled
one complete cycle without holding the palm buttons. Requires guarding.
FS-02 Floor Stand with adjustable leveling swivels.
LCG1 Light Curtain Guarding:
Full perimeter guarding.
Front mounted light curtain guarding includes emitter, detector,
mounting hardware and installation.
Fixed guarding on both sides using wire mesh.
Air to Oil Cooling System with dedicated hydraulic cooling pump
and hydraulic filter.
Recommended for dwell applications over 3 sec and high cycle applications.
SRDC-2.0 Split Ring Die Coupler
Standard Bolster comes plain. Magnum can provide custom machining.
Structural Designs undergo rigorous analysis through Finite Element Analysis design testing
Allen Bradley MicroLogix PLC with Panel View HMI based controls
Single Point Power Connection 2-Hand Anti-Tie-Down Start Buttons CAT 4 Safety Start Relay
NEMA 12 enclosures NFPA-79 / UL 508A Compliant Electrical Controls
High Temp/Low Level Warning Gauge Magnetic Starter/ Electronic Overload
Lockable Disconnect Press mounted controls.
Primary power flow for press functions is handled by a CAT 4 two-hand anti-tie down safety relay. This specialty relay checks complementary inputs from each cycle initiator to insure the operators hands are out of the work area.
Top Stop Over-Run allows press to bypass top stop RAM setting in setup modes
Pressure and Distance Reversal Mode allows operator to select between pressure or position reversal
All wiring is terminated to spring cage style terminals. These terminals provide reliable vibration resistant connections. Wiring on the panel is routed through wire troughs with removable covers.
All PLC I/O points are also terminated to the terminals. Systems include multiple guard terminals already installed. Inputs and outputs have all necessary connections (power for proximity switches and grounds and neutrals for coils) on a single terminal, no searching for support wiring for devices.
All valve coils use DIN 43650 connections with power indicator lighting and electrical EMF surge suppression.
A simple, removable and easily serviceable press mounted press hydraulic system powers the press
The heart of the hydraulic system features an efficient steel manifold designed to consolidate valving, reduce plumbing, eliminate leaks, minimize pressure drop and provide maximum service life.
Efficient Screw In Cartridge Valves (SICV) solenoid valves have extremely low leakage, low pressure drops, low cost low current operation and simple maintenance. Piloted DIN logic elements outperform large piloted spool valves in leakage, flow and response time. Valve shift times are 30% of comparable piloted spool valves resulting in increased press cycle speeds.
Manifold System offers redundant safety feature which requires 3 solenoids to be energized before there can be any movement of the RAM in extend or retract. Failure of any single component will result in no hazardous motion of press RAM.
Electro-Hydraulic Decompression with FAST ACTING 3 stage decompression offering resistance to damaging decompression pressure spikes that is far superior to hydraulic or mechanical decompression used in other presses.
All final pressure connections use Flat Face O-Ring Hydraulic Connections to provide the most leak resistant hydraulic system. No metal to metal pressure connections and no pipe thread are used.
PDF manual with startup instructions, troubleshooting guide, hydraulic circuit with manufacturers part number bill of material, electrical diagram and PLC program.
18 month parts warranty against defects in workmanship