Overview
Manufacturer:
BAC
Stock #:
53694002
Status:
For Sale
Description

Used BAC Baltimore Air Coil Model S15E-1212-12KN-2/L Series 1500 Double Cell Cooling Tower. 802 Nominal Tonnage. Based on 95 degrees F entering water temperature to an 85 degrees F leaving water temperature at a 78 degrees F entering wet-bulb temperature. Galvanized panels. (2) 66" diameter Axial Fans. Hinged access door. 316 Stainless Steel Cold water basin. Serial# U211999901-01-2. Built 2021.

Specifications

Used Equipment Facts About This Machine
The BAC (Baltimore Aircoil) Series 1500 Double Cell Cooling Tower, Model S15E-1212-12KN-2/L is a part of the BAC's renowned Series 1500 range, designed for efficient heat rejection in industrial and commercial applications. The Series 1500 cooling towers are known for their compact, high-performance, and energy-efficient design. Below is a detailed overview of the S15E-1212-12KN-2/L model:
Key Features of BAC Series 1500 Double Cell Cooling Tower, Model S15E-1212-12KN-2/L:

High Efficiency:

The S15E-1212-12KN-2/L model is engineered for high thermal efficiency, utilizing advanced design features to maximize heat transfer while minimizing energy consumption. The efficient heat exchange process reduces operating costs, especially in large-scale systems.

Double Cell Design:

The double-cell configuration provides a more compact, space-saving design while still delivering high cooling capacity. This makes the model ideal for facilities with limited space but high cooling needs, such as industrial plants or commercial buildings.

Durable and Corrosion-Resistant Construction:

The cooling tower is constructed using materials designed for durability and resistance to corrosion. It typically features a galvanized steel frame, stainless steel components, and fiberglass-reinforced plastic (FRP) components, ensuring a long service life even in harsh environments.

Low Operating Noise:

The S15E-1212-12KN-2/L model is designed to operate quietly, making it suitable for installations in areas where noise levels are a concern, such as residential neighborhoods or urban settings.

Energy-Efficient Fans:

The cooling tower is equipped with energy-efficient fans that reduce power consumption. The fans are designed for optimal airflow and low power consumption, helping to keep energy costs under control while maintaining effective heat dissipation.

Easy Maintenance and Serviceability:

The Series 1500 cooling towers, including the S15E-1212-12KN-2/L, are designed for ease of maintenance. The components are easily accessible for inspection, cleaning, and service, minimizing downtime and maximizing operational efficiency.

Variable Flow Options:

The model allows for flexibility in operation with adjustable water flow rates, making it adaptable to a wide range of applications and enabling more precise control over the cooling process.

Compact and Modular Design:

The modular design of the BAC Series 1500 allows for easy installation and scalability. This makes it easy to add additional units if cooling requirements increase over time.

Advanced Water Distribution System:

The model features an optimized water distribution system designed to ensure uniform water flow across the fill media, which maximizes heat transfer efficiency and minimizes the potential for fouling.

Applications of the BAC Series 1500, Model S15E-1212-12KN-2/L:
The S15E-1212-12KN-2/L model is designed for use in a variety of industrial and commercial applications, including:

HVAC Systems:

The cooling tower is commonly used in large building air conditioning systems to reject excess heat from cooling systems, ensuring that air conditioning and refrigeration equipment operate efficiently.

Power Plants:

It is often used in power plants, where it helps cool the water used in the power generation process, particularly in steam turbine cooling.

Industrial Cooling:

The cooling tower is used in various industrial applications, including chemical plants, petrochemical plants, refineries, and food processing, where large-scale heat dissipation is necessary.

Data Centers:

Used in data centers to cool the large amounts of equipment generating heat, ensuring efficient operation of servers and other IT infrastructure.

Oil and Gas Industry:

Oil refineries and other facilities in the oil and gas sector use the cooling tower to remove excess heat from cooling systems used in refining processes.

Wastewater Treatment:

The cooling tower may also be utilized in cooling systems for wastewater treatment plants to manage heat produced during treatment processes.

District Cooling Systems:

Suitable for use in district cooling systems that serve multiple buildings or entire complexes, providing centralized cooling to a wide array of structures.

Specifications (Typical for BAC Series 1500, Model S15E-1212-12KN-2/L):
Although specific specifications can vary by configuration, the general features and capabilities of the S15E-1212-12KN-2/L are as follows:

Cooling Capacity: Typically ranges from 250 to 1,500 tons (depending on system configuration and water temperature).
Fan Type: Axial flow fans designed for high efficiency and low noise.
Water Flow: Typically, water flow rates range from 1,000 to 3,000 GPM (gallons per minute), depending on cooling requirements.
Construction Materials: Galvanized steel frame, fiberglass-reinforced plastic (FRP) casing, and stainless steel components for corrosion resistance.
Dimensions: The double-cell design reduces the footprint of the tower, making it suitable for installations where space is limited. The precise dimensions will depend on the configuration and cooling capacity.
Power Requirements: Motor power typically ranges from 15 to 60 kW depending on fan size and system configuration.
Noise Level: Designed for quiet operation with low noise levels, typically below 80 dB(A), making it suitable for urban or residential installations.

Advantages of BAC Series 1500, Model S15E-1212-12KN-2/L:

Compact Footprint: The double-cell design reduces the space required for installation while still delivering high cooling capacity.
Energy Efficiency: The energy-efficient fans and optimized water distribution system help reduce overall energy consumption, lowering operating costs.
Quiet Operation: Low noise levels make the model ideal for installations in noise-sensitive areas.
Durability and Longevity: Corrosion-resistant construction ensures that the cooling tower will last for many years, even under harsh environmental conditions.
Ease of Maintenance: The modular design and accessible components make it easier to maintain and service, reducing downtime.
Scalability: The modular nature allows for the addition of more units if cooling needs increase over time.

Maintenance and Service:

Routine Maintenance: Regular inspections of fans, motors, water distribution system, and fill media are recommended to ensure the cooling tower operates efficiently.
Cleaning: The tower should be cleaned periodically to prevent scaling and fouling of the heat exchange surfaces.
Service: BAC offers a range of services, including commissioning, maintenance, and troubleshooting support to keep the cooling tower running at peak performance.

Conclusion:
The BAC Series 1500 Double Cell Cooling Tower, Model S15E-1212-12KN-2/L, is an excellent choice for applications that require high-efficiency heat rejection in a compact, energy-efficient design. Its durability, ease of maintenance, and adaptability to various industrial and commercial settings make it a reliable solution for cooling in power plants, HVAC systems, data centers, and more. With its modular design and efficient performance, the S15E-1212-12KN-2/L is an ideal solution for facilities with both space and energy efficiency concerns.
PRODUCT DETAILS
Double Cell Cooling TowerBAC Series 1500Industrial cooling towerModular cooling towerHVAC cooling towerCooling tower for commercial buildingsCooling tower for industrial plantsData center cooling towerCompare BAC Series 1500 to other cooling tower brandsEnergy-efficient cooling towers for commercial buildingsCommercial Cooling Tower